| Performance Test: |
| Electrical Tests in accordance
with UL performance program and ASTM D-4566. |
| TEST
ITEM |
UNIT |
CHARACTERISTICS |
REMARKS |
|
Conductor Resistance |
(
)/100mm |
Max.
9.38 |
At
20ºC |
| DC
Resistance Unbalance |
% |
Max.
5 |
4 |
|
Continuity Test of Conductor |
-- |
Shall
be connected |
4 |
| Pair
to ground capacitance unbalance |
Pf/100m |
Max.
330 |
4 |
|
| |
Freqency
MHz
|
Characteristic
Impedance (W) |
Attenuation
Max. dB/100 |
Next
Max. dB> 100m |
S.R.L.
Min. dB |
|
0.246 |
- |
- |
- |
- |
|
0.512 |
- |
- |
- |
- |
|
0.772 |
102+/-15% |
1.8 |
64 |
- |
| 1.0 |
100+/-15% |
2.0 |
62 |
23 |
| 4.0 |
100+/-15% |
4.1 |
53 |
23 |
| 8.0 |
100+/-15% |
5.8 |
48 |
23 |
| 10.0 |
100+/-15% |
6.5 |
47 |
23 |
| 16.0 |
100+/-15% |
8.2 |
44 |
23 |
| 20.0 |
100+/-15% |
9.3 |
42 |
23 |
| 25.0 |
100+/-15% |
10.4 |
41 |
22 |
|
31.25 |
100+/-15% |
11.7 |
39 |
21 |
|
62.5 |
100+/-15% |
17.0 |
35 |
18 |
| 100.0 |
100+/-15% |
22.0 |
32 |
16 |
|
| |
| Physical Properties: |
| TEST
ITEMS |
UNIT |
CHARACTERISTICS |
REMARKS |
Insulation
(HPDE) |
Unaged |
Tensile
Strength |
Kgf/mm |
Not
less than 1.69 |
- |
| Elongation |
% |
Not
less than 300 |
- |
| After
Aged |
Tensile
Strength |
Kgf/mm |
Not
less than 75% of before aging value |
100ºC/48hrs |
| Elongation |
% |
Not
less than 75% of before aging value |
Insulation
(SRPVC) |
Unaged
|
Tensile
Strength |
Kgf/mm |
Not
less than 2.12 |
- |
| Elongation |
% |
Not
less than 100 |
- |
| After
Aged |
Tensile
Strength |
Kgf/mm |
Not
less than 70% of before aging value |
113ºC/168hrs |
| Elongation |
% |
Not
less than 70% of before aging value |
Jacket
(PVC) |
Unaged
|
Tensile
Strength |
Kgf/mm |
Not
less than 1.41 |
- |
| Elongation |
% |
Not
less than 100 |
- |
| After
Aged |
Tensile
Strength |
Kgf/mm |
Not
less than 75% of before aging value |
100ºC/240hrs |
| Elongation |
% |
Not
less than 50% of before aging value |
|
Insulation shrink back |
mm |
Max
9.5 |
In
case of using Rip Cord |
|
Jacket peel test |
mm |
Max.
30 sec |
- |
|
Cold Bend test of insulation |
- |
No
cracks |
- |
|
Cold Bend test complete cable |
- |
No
cracks |
- |
|
Flame test |
- |
VTFT |
- |
|
| |
| Insulation and Twisted
Pair Colors: |
| No.
of Pairs |
Colors |
| 1 |
Blue-White/Blue |
| 2 |
Orange-White/Orange |
| 3 |
Green-White/Green
|
| 4 |
Brown-White/Brown |
|
|
|
| |
| Ordering Information: |
| Item# |
Description |
Color |
| 9805041 |
UTP
4-Pair Cat-5e PVC CM 1,000 Ft Cable |
Gray |
| 9805041 |
UTP
4-Pair Cat-5e PVC CM 1,000 Ft Cable |
Blue |
|
|
| |